Master terminal MT-07 IP
Patient terminal PT-07DS IP
Patient unit PU-07R IP
Connection module CM-07 CP IP
Connection module CM-07 DP IP
Connection module CM-07LAN
Bed connection BC-07HS IP_ Connection module CM-07LAN
Cancel button CC-07 IP
Doctor call button DC-07 IP
Room terminal RT-07 IP
Room terminal RT-07D IP
Room terminal RT-07DCR IP
Room terminal RT-07V IP
Emergency button EB-07 IP
Emergency pull cord EC-07 IP
Corridor lamp (LED) CL
Connector VoIP-LAN
Data switch 16 port RT-07 IP
Service terminal (entrance) ST-07V IP
Optical and Acoustic Nurse Call Signaling System HCC-01.5
Call-out System
Master terminal MT-07 IP
The master terminal centralizes the operation of the communication equipment in a room with permanent service, which in most cases is the nurses' office. The terminal offers a highly comfortable and clearly arranged graphic user environment linked with simple operation and control of functional buttons directly on the operating graphic touch-screen display.
Patient terminal PT-07DS IP
- It is intended for listening to entertainment programs and discreet or speakerphone voice calls of the patient on the master terminal MS-07 IP or calling an "expert" nurse using a large red button (backlit at night) with a nurse symbol. It also allows the calling of "ancillary" personnel using the "coffee" symbol button.
- In combination with the light relay LR-07 it allows the controlling of one light in the room (on/off function).
- In the standby mode the display shows the current time, in the case of switching to the option entertainment program, it indicates the current number of the program (1, 2 ...).
Patient unit PU-07R IP
- This is a simpler variant of the patient terminal. It allows only speakerphone communication of the patient only with the nurse and listening to the entertainment program from a speaker which is part of the bed connection BC-07S IP or BC-07HS IP.
- The choice between patient unit or patient terminal depends primarily on the users of the equipment.
- This type of element cannot be used with the variant of bed connection without speaker.
- Neither is it possible to switch between entertainment programs – the first program is always selected (the element does not contain keys allowing the switching of programs).
Connection module CM-07 CP IP
- The module allows the activation of certain, and deactivation of all, types of calls within a room directly at a bed and may replace the room terminal in special cases.
- It is possible to control the LED CL lamp directly from the module or activate emergency calling.
- In contrast with the room terminal, this module does not allow the taking of voice calls and registration of ancillary personnel.
Connection module CM-07 DP IP
- Using the blue button the module allows the activation of a doctor call or alarms, for example "BLUE CODE" etc.
- The second green button serves for the registration of the nurse and deactivation of all types of calls in a given ward directly at the bed.
- In special cases it is possible to control the LED CL lamp directly from the module or activate an emergency call from a WC (after running the relevant cable from the buttons to the WC).
- This module does not allow the taking of voice calls.
Connection module CM-07LAN
- The module allows the connection of any equipment (most often PC) to the Ethernet (LAN) using a connector RJ-45 – 8p8c in the same design as the other elements of the equipment located near or in a common frame.
- Inside the module there is a standard "keystone" CAT-5E 100Mb allowing direct fitting of the inlet cable.
Bed connection BC-07HS IP Connection module CM-07LAN
- The connection with speaker serves for the direct hanging and connection of bed connections and patient units.
- In combination with the patient terminal it allows the selection of speakerphone voice connection and listening to an entertainment program and discrete connection, with the patient unit only speakerphone listening to program and voice connection.
- The connector for connection of the patient terminal leads out from the bottom of the element on the position of the holder.
Cancel button CC-07 IP
- The button serves primarily for deactivating of emergency calls usually in a bathroom or WC, which is part of a ward.
- It is located near the door in the bathroom or toilet.
Doctor call button DC-07 IP
- The ALARM button allows the direct activation of a high priority "ALARM" call.
- It is usually only possible to activate this calling by pressing a combination of buttons on the room terminal so that there can be no abuse or unwanted activation in operation.
- It serves for the immediate calling of assistance, for example of further medical personnel or a doctor to the given room.
Room terminal RT-07 IP
- Room terminal without speaker.
- It is used in particular in rooms where voice connection and central announcement is not required – for example, separate bathroom, WC, cleaning cupboard etc.
- After registration of personnel using the relevant button, information is sent optically and acoustically about the incidence of any type of call at the department.
- It makes it possible to terminate all types of calls from the given room without the need of receipt of the call on the master terminal.
- This terminal does not contain a speaker, and it is not possible to make a voice call from it or to receive a central announcement.
Room terminal RT-07D IP
- Room terminal with display and loudspeaker.
- An information display is fitted allowing the identification of the place where a call originated and its type.
- In the standby state the date and time are displayed, in the case that a call is made, if the worker is registered, the room number, bed and type of call is displayed.
- It is usually used in wards or doctors' or nurses' duty rooms.
Room terminal RT-07DCR IP
- Room terminal with display, loudspeaker and integrated RFID card reader.
- Usually only used in wards.
- It has integrated RFID reader which allows the registration of personnel in a room with direct recording in the system history. Each worker (nurse doctor etc.) has their own wireless ID card.
Room terminal RT-07V IP
- Room terminal with loudspeaker and possibility of voice connection.
- This room terminal is used in particular in wards or duty rooms of doctors and nurses.
- After registration of personnel using the relevant button, information is sent optically and acoustically about the incidence of any type of call at the department.
- It also makes it possible to terminate all types of calls from the given room without the need of receipt of the call on the master terminal.
Emergency button EB-07 IP
- This is a switch allowing the activation of an emergency call to the system in connection with the room terminal.
Emergency pull cord EC-07 IP
- The function is similar to the emergency call button. But it has a switch with a cord for simpler use from a bath, shower etc.
Corridor lamp (LED) CL
- This has three color-coded lights signaling the state and type of calling in the given place in connection with the room terminal.
- It is located visibly in the corridor, with the exception of duty rooms, above the door of each ward, separate bathroom and WC.
Connector VoIP-LAN
Data switch 16 port RT-07 IP
Service terminal (entrance) ST-07V IP
- This allows speakerphone connection with between for example family members and the nurses' office.
- Located primarily at entry door to department.